Marque:NANBEI
Modèle:MP522
Application:
MP522 Precision pH/Conductivity Meter
Introduction
● There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode. |
● Automatically recognize 13 kinds of pH buffer solution. User can choose anyone from four series of standard buffer solutions: Europe & USA series, NIST series, CHINA series and Self-defined series. |
● High purified water and ammonia added purified water pH measuring mode can be set up, especially suitable for electric power and petrochemical industry. |
● With EH redox potential measuring mode can directly display ORP value which against standard potential of hydrogen electrode. |
● Automatically recognize 8 kinds of conductivity standard solution. User can choose anyone from two series of solutions: Europe & USA series and China series. |
●Adopt advanced and original conductivity measurement technology, use 1 pc of conductivity electrode (K=1), it can meet measuring accuracy requirement for range within 0.5μS/cm ~ 200mS/cm by using only one-point calibration. |
●Automatically select conductivity measurement range, when measuring high pure water, equipment automatically enter into temperature compensation of nonlinear model, especially for electricity, microelectronics and the pharmaceutical industry requirements. |
● Meter has the only product serial number. |
● Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps. |
●Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc. |
Specifications
pH |
Measuring range Resolution Accuracy Input current Input impendance Stability Temp. compensation range |
(-1.999 ~ 19.999)pH 0.1/0.01/0.001 pH Meter:±0.002 pH, connect meter with electrode:±0.01pH ≤1×10-12 A ≥3×1012 Ω ±0.002 pH/3h (0 to 100) ℃(automatic or manual) |
mV |
Measuring range(mV/ORP/EH) Resolution Accuracy |
-1999.9mV ~ 0 ~ 1999.9mV 0.1mV ±0.03% FS |
Conductivity |
Measuring range Resolution Accuracy Temp. compensation range Electrode constant Reference temperature |
Conductivity:(0.00~20.00)μS/cm (20.0~200.0)μS/cm (200~2000)μS/cm (2.00~20.00)mS/cm (20.0~200.0)mS/cm (200~2000)mS/cm(K=10) Resistivity:(0 ~ 100)MΩ·cm TDS: (0 ~ 100)g/L Salinity: (0 ~ 100)ppt 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm Meter:±0.5% FS,connect meter with electrode:±0.80% FS (0 ~ 50)℃(automatic ) 0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1 25℃、20℃ and 18℃ |
Temperature |
Measuring range Resolution Accuracy |
-10℃~ 110℃ 0.1℃ 5~ 60℃range:±0.4℃ other range:±0.8℃ |
Other Technical Parameters: |
Data storage Storage content Power Communication connector Size and weight Quality and safety certification |
300 groups Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time DC9V/300mA RS232 160 × 190 × 70mm/880g ISO9001:2008, CE and CMC |
Working Condition |
Environment temperature Environmental humidity IP rating |
5 ~ 35 ℃(0.01grade) 15 ~ 30 ℃(0.001grade) ≤75% IP54 Dustproof and waterproof |
Standard Kit Includes
1. Model MP522 Precision pH/Conductivity meter | 1set |
2. Model 602 flexible electrode holder | 1pc |
3. 201T-M plastic pH/ATC three-in-one combination electrode | 1pc |
4.2503-C glass pH combination electrode | 1pc |
5. MP500 temperature electrode | 1pc |
6. 2401-M conductivity electrode | 1pc |
7. pH standard buffer solution(pH4.00, pH7.00 and pH10.01/50mL) | 1btl/each |
8. 1413μS/cm conductivity standard solution(50mL) | 2btls |
9. 9V power adapter(meter use)e | 1pc |
10. RS-232 communication cable | 1pc |
11. MP522 communication software disk | 1pc |
12. Operation manual | 1unit |
13. Brief operation instruction | 1unit |